Summary for Test 2024-02-12-48-6

Test performed: ASTM D2369-Jul10

Project Information

Project IdentifiersProject ID: 213457
DEA: 11430434
EFIS: 1118000197
DIST-CO-RTE-PM11-SD-8-12.9/14.6,14.9
Award Date07/16/2022
Closeout Date08/21/2025
Work DescriptionHMA, STRUCTURAL BRIDGE, POLYESTER CONC OVERLAY, JPCP, & CONC BARRIER.
Location DescriptionSAN DIEGO COUNTY IN LA MESA AND EL CAJON FROM 0.1 MILE WEST OF GROSSMONT BOULEVARD OVERCROSSING TO WEST MAIN STREET OVERCROSSING AND AT MARSHALL AVENUE OVERHEAD
QA Service Level1 (Verified on 06/22/2018)

Sample Information

Sample Taken Date02/12/2024 Sample Unique Key48
Date that the sample was received by the laboratory/organization performing the testing02/13/2024 Sample typeQuality Control
A brief description of the sample1 gallon can / PPC 1121 RESIN The quantity of what the sample constitutes2 tankers
From where was the sample collectedSource First name of sampler or witnessed byGILBERTO
Last name of sampler or witnessed byGONZALEZ Title of samplerQuality Control Manager
Telephone number of sampler17076245467 Laboratory sample identification000036KBP
Linked DIME Sample ID000036KBP The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia
Transportation Laboratory (TL) NumberSacramento Caltrans lab Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)AZ4B00158
Batch NumberAZ4B00158 Mix numberAZ4B00158

Test Details

DIME Sample ID: 2024-02-12-48
DIME Test ID: 2024-02-12-48-6
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Test Release Date: 2024-03-19

Test Results


Input Type: Calculated
Tester's full name: Mariano Pontillas
Date of test: 03/04/2024
Mean of two volatile content determination: 44.9
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/19/2024 ✔