Summary for Test 2024-03-12-4-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 215425 DEA: 06360244 EFIS: 0613000005 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-99-30.6/35.2 |
| Award Date | 04/23/2021 |
| Closeout Date | Not set |
| Work Description | Widen Freeway & Bridge Construction (Concrete Bridge) |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
| Sample Taken Date | 03/12/2024 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/12/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Class 2 Aggregate Base |
| The quantity of what the sample constitutes | 2000 sq ft per CTM 231 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Neale | Last name of sampler or witnessed by | Brown |
| Title of sampler | Materials Tester | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Jobsite | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Test holes at jobsite | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-03-12-4
DIME Test ID: 2024-03-12-4-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-03-13
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: Yes
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 03/12/2024
Gage No.: 25768
Test No.: 610
Nuclear By: Neale Brown
Non-Bias Plan No.: 2 even
Depth: 8
Material No.: no data
Material Type: Class 2 AB recycled
Impact By: Jason Ruiz
Standard Count Density: 1824 g/cc
Count or Density 1: 827 g/cc
Count or Density 2: 949 g/cc
Count or Density 3: 947 g/cc
Count or Density 4: 902 g/cc
Count or Density 5: 994 g/cc
Standard Count Moisture: 650 g/cc
Moisture Count 1: 146 g/cc
Moisture Count 2: 135 g/cc
Moisture Count 3: 123 g/cc
Moisture Count 4: 115 g/cc
Moisture Count 5: 112 g/cc
Density: 2.16
Moisture: 0.16
Sum of Count or Density: 4619 g/cc
Average of Count or Density: 924 g/cc
Sum of Moisture Count: 631 g/cc
Average of Moisture Count: 126 g/cc
Count Ratio Density: 0.51
Count Ratio Moisture: 0.19
Calculated Percent Relative Compaction: 98 %
Reported Percent Relative Compaction: 98 %
General comments (publicly viewable) (Max 1000 characters): SB 99 Station 176-90 to 180+80 elevation: .95'BFG width: 46ft
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 06-360244_37000_240312_608to617 | 2123.07 KB | 03/13/2024 | 2024-03-12-4-1 | Info |
Test was verified on 3/13/2024 ✔