Summary for Test 2024-03-03-1-5

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 994574
DEA: 050C7334
EFIS: 0518000116
DIST-CO-RTE-PM05-SCR-1-10.5/13.4
Award Date06/29/2023
Closeout DateNot set
Work DescriptionCONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location DescriptionSANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
QA Service Level1 (Verified on 04/13/2023)

Sample Information

Sample Taken Date03/03/2024 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing03/04/2024 Sample typeDepartment Acceptance
A brief description of the samplePG64-16 ARB The quantity of what the sample constitutes1 Can
From where was the sample collectedSource First name of sampler or witnessed byMarco
Last name of sampler or witnessed byMONTIEL Title of samplerQC
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNational Blending Company
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number23_1696

Test Details

DIME Sample ID: 2024-03-03-1
DIME Test ID: 2024-03-03-1-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2024-03-21

Test Results


Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 03/11/2024
Temperature: 25 C
Ball Penetration (P1): 5 mm
Final Dial reading (F1): 60 mm
Ball Penetration (P2): 2 mm
Final Dial reading (F2): 60 mm
Ball Penetration (P3): 2 mm
Final Dial reading (F3): 60 mm
Resilience 1: 45 %
Resilience 2: 42 %
Resilience 3: 42 %
Average Resilience: 43 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/21/2024 ✔