Summary for Test 2024-02-23-35-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995261
DEA: 072XJ804
EFIS: 0724000004
DIST-CO-RTE-PM07---
Award Date07/28/2023
Closeout Date04/24/2024
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 11/09/2023)

Sample Information

Sample Taken Date02/23/2024 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/08/2024
Sample typeDepartment Acceptance A brief description of the sample3/8" HMA-A DIKE 109426
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byZubieta
Title of samplerTEC Telephone number of sampler
Laboratory sample identification24-031 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA Corona Transportation Laboratory (TL) Number021324
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/8 inch Lot number
Sublot number HMA Mix Number109426
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-02-23-35
DIME Test ID: 2024-02-23-35-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-03-11

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Chad Chotibhongs
Date of test: 03/11/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4024.3 g
Mass of the specimen and specimen basket assembly prior to ignition: 5547.0 g
Mass of HMA Sample prior to ignition: 1522.7 g
Mass Loss: 97.5 g
Mass of aggregate remaining after ignition: 1425.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.40 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/11/2024