Summary for Test 2024-02-12-33-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 993662
DEA: 061A6404
EFIS: 0620000176
DIST-CO-RTE-PM06-FRE-41,180-R23.1,R58.7
Award Date05/20/2022
Closeout Date04/24/2024
Work DescriptionPLACE POLYESTER CONCRETE OVERLAY AND REPLACE JOINT SEAL ASSEMBLY.
Location DescriptionFRESNO COUNTY IN FRESNO ON ROUTE 41 AT VENTURA AVENUE VIADUCT AND ON ROUTE 180 AT ROUTE 180/41 CONNECTOR SEPARATION
QA Service Level1 (Verified on 04/04/2022)

Sample Information

Sample Taken Date02/12/2024 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/13/2024
Sample typeDepartment Acceptance A brief description of the sample4x8 concrete cylinders
The quantity of what the sample constitutes6 4x8 Cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byJuan Last name of sampler or witnessed byDe La Torre
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility name? Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberND22023
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected000
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedmedian rail Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-02-12-33
DIME Test ID: 2024-02-12-33-2
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-03-11

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 03/11/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 75390 lb
Maximum load on cylinder 2: 82850 lb
Maximum load on cylinder 3: 75940 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5997.6 psi
Compressive strength of cylinder 2: 6591.1 psi
Compressive strength of cylinder 3: 6041.4 psi
Compressive strength (to nearest 10 psi): 6210 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/11/2024