Summary for Test 2024-02-24-5-1

Test performed: ASTM D217-16

Project Information

Project IdentifiersProject ID: 213405
DEA: 120R5504
EFIS: 1218000116
DIST-CO-RTE-PM12-ORA-74-0.47
Award Date05/24/2018
Closeout Date07/01/2024
Work DescriptionRemove and replace a damaged traffic light pole with new mast arm, signal head and place new concrete pole pile foundation.
Location DescriptionIn Orange County on Route 74 at La Novia Intersection in the City of San Juan Capistrano
QA Service Level1 (Verified on 06/05/2018)

Sample Information

Sample Taken Date02/24/2024 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/06/2024
Sample typeVerification A brief description of the sampleTEST Asphalt Rubber Binder
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byDavid Last name of sampler or witnessed byNguyen
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2024-02-24-5
DIME Test ID: 2024-02-24-5-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2024-03-12

Test Results


Determination: Unworked Penetration
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 03/06/2024
Unworked Penetration: 33 0.1 mm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/12/2024