Summary for Test 2024-02-24-5-2
Test performed: ASTM D36-14ε1Project Information
Project Identifiers | Project ID: 213405 DEA: 120R5504 EFIS: 1218000116 |
---|---|
DIST-CO-RTE-PM | 12-ORA-74-0.47 |
Award Date | 05/24/2018 |
Closeout Date | 07/01/2024 |
Work Description | Remove and replace a damaged traffic light pole with new mast arm, signal head and place new concrete pole pile foundation. |
Location Description | In Orange County on Route 74 at La Novia Intersection in the City of San Juan Capistrano |
QA Service Level | 1 (Verified on 06/05/2018) |
Sample Information
Sample Taken Date | 02/24/2024 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/06/2024 |
Sample type | Verification | A brief description of the sample | TEST Asphalt Rubber Binder |
The quantity of what the sample constitutes | 1can | From where was the sample collected | Source |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Nguyen |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | AAA-Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2024-02-24-5
DIME Test ID: 2024-02-24-5-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2024-03-12
Test Results
ASTM Thermometer used?: C
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 03/05/2024
Softening Point Sample 1: 58 C
Softening Point Sample 2: 58 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/12/2024 ✔