Summary for Test 2024-03-05-15-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 994351 DEA: 07322004 EFIS: 0716000053 |
---|---|
DIST-CO-RTE-PM | 07-LA-118-R11.0/R14.0 |
Award Date | 01/11/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT STORMWATER TREATMENT DEVICES. |
Location Description | THE CITY AND COUNTY OF LOS ANGELES FROM 0.1 MILE WEST OF ARLETA AVENUE UNDERCROSSING TO 0.1 MILE WEST OF ROUTE 118/210 SEPARATION |
QA Service Level | 1 (Verified on 06/08/2023) |
Sample Information
Sample Taken Date | 03/05/2024 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/05/2024 |
Sample type | Department Acceptance | A brief description of the sample | Subgrade |
The quantity of what the sample constitutes | 750 CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Lou Ralph | Last name of sampler or witnessed by | Achuela |
Title of sampler | TET | Telephone number of sampler | 2138170504 |
Laboratory sample identification | 24-0396 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Design Built Engineering | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Subgrade |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | From various locations at subgrade | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-03-05-15
DIME Test ID: 2024-03-05-15-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-03-13
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Lou Ralph Achuela
Date of test: 03/05/2024
Gage No.: 31104
Test No.: 2
Nuclear By: Lou Ralph Achuela
Non-Bias Plan No.: 2
Depth: 12''
Material No.: On-Site
Material Type: Subgrade
Impact By: Lou Ralph Achuela
Standard Count Density: 2042 g/cc
Count or Density 1: 291 g/cc
Count or Density 2: 258 g/cc
Count or Density 3: 368 g/cc
Standard Count Moisture: 662 g/cc
Moisture Count 1: 109 g/cc
Moisture Count 2: 144 g/cc
Moisture Count 3: 109 g/cc
Sum of Count or Density: 917.00 g/cc
Average of Count or Density: 306.00 g/cc
Sum of Moisture Count: 362.00 g/cc
Average of Moisture Count: 121.00 g/cc
Count Ratio Density: 0.15
Count Ratio Moisture: 0.18
Calculated Percent Relative Compaction: 93 %
Reported Percent Relative Compaction: 93 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/13/2024 ✔