Summary for Test 2024-02-26-37-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676 |
---|---|
DIST-CO-RTE-PM | 04-SOL-80-R10.4/30.2 |
Award Date | 01/18/2022 |
Closeout Date | Not set |
Work Description | Highway widening, overhead signs, and electronic toll system. |
Location Description | In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
Sample Taken Date | 02/26/2024 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/26/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
Title of sampler | Lab Technician | Telephone number of sampler | 7072999133 |
Laboratory sample identification | Con_24_090 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Vallejo Batch Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 10 |
Sublot number | 7 | HMA Mix Number | 220991W |
Test Details
DIME Sample ID: 2024-02-26-37
DIME Test ID: 2024-02-26-37-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-03-07
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 03/06/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2192.0 g
Mass Loss: 155.1 g
Correction Factor (Percent by mass of HMA Specimen): 1.83 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.11 %
General comments (publicly viewable) (Max 1000 characters): Range 5.1 - 5.9
Test was verified on 3/7/2024 ✔