Summary for Test 2024-01-16-16-5
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/16/2024 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/16/2024 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | Washed Sand |
The quantity of what the sample constitutes | 6 bags of virgin aggregate | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Antonio | Last name of sampler or witnessed by | Ramirez |
Title of sampler | QC Technician | Telephone number of sampler | 8054064937 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite Construction Gardner Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-42-0022 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Sampled at Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-01-16-16
DIME Test ID: 2024-01-16-16-5
Testing Lab: Granite Construction Company - Santa Paula
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-03-07
Test Results
Number of tests: 3
Input Type: Calculated
Tester's full name: Antonio Ramirez
Date of test: 01/18/2024
Temperature correction: 0
Temperature of solution: 73
Clay reading (test 1): 4.1
Sand reading (test 1): 3.5
Clay reading (test 2): 5.3
Sand reading (test 2): 4.4
Clay reading (test 3): 4.9
Sand reading (test 3): 3.9
Sand equivalent (test 1): 86
Sand equivalent (test 2): 83
Sand equivalent (test 3): 80
Sand equivalent before temperature correction: 83
Sand equivalent after temperature correction: 83
General comments (publicly viewable) (Max 1000 characters):