Summary for Test 2024-02-21-19-2

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date02/21/2024 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/01/2024
Sample typeQuality Assurance A brief description of the sample3/4 HMA and cores
The quantity of what the sample constitutes100 Tons From where was the sample collectedSupplier
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byRingler
Title of samplerLab Technician Telephone number of sampler7078161520
Laboratory sample identificationCon_24_085 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Vallejo Batch Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number10
Sublot number4 HMA Mix Number220991W

Test Details

DIME Sample ID: 2024-02-21-19
DIME Test ID: 2024-02-21-19-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-03-05

Test Results


Number of tests: 1
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 03/01/2024
Percent Air Voids: 95.7 %
General comments (publicly viewable) (Max 1000 characters): LOT 10 SUBLOT 4

Test was verified on 3/5/2024