Summary for Test 2023-08-20-16-2
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 994543 DEA: 023J7604 EFIS: 0222000081 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-273-12.8/14.6 |
| Award Date | 04/25/2023 |
| Closeout Date | 04/11/2024 |
| Work Description | COLD PLANE ASPHALT CONCRETE PAVEMENT AND PLACE RUBBERIZED HMA-G. |
| Location Description | SHASTA COUNTY IN REDDING FROM 0.1 MILE NORTH OF CEDARS ROAD/S BONNYVIEW ROAD TO 0.1 MILE NORTH OF BUENAVENTURA BOULEVARD |
| QA Service Level | 1 (Verified on 08/07/2023) |
Sample Information
| Sample Taken Date | 08/20/2023 | Sample Unique Key | 16 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/21/2023 | Sample type | Production Start-Up |
| A brief description of the sample | 16 boxes of Lime Treated 1/2-inch RHMA-G (PG 64-16 CR) | The quantity of what the sample constitutes | Production Start-Up Evaluation |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Cindy |
| Last name of sampler or witnessed by | Bryant | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | D79333 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) | |
| Transportation Laboratory (TL) Number | 866066 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | JMF3513202318 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-08-20-16
DIME Test ID: 2023-08-20-16-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-03-07
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 08/21/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.1 grams
Mass of oven-dry sample in air for Sample 1: 1505.8 grams
Mass of container filled with the sample and water for Sample 1: 8211.8 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.394
Theoretical maximum density at 25°C (77°F): 2387.1 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmm=2.394