Summary for Test 2024-02-06-28-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 1000135 DEA: 024H7504 EFIS: 0219000058 |
---|---|
DIST-CO-RTE-PM | 02--299-49/72 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Poker Bar Culverts |
Location Description | TRI 299 PM 49.0-72.0 |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/06/2024 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/06/2024 |
Sample type | Preliminary | A brief description of the sample | Soil for culvert recommendation, C-8 |
The quantity of what the sample constitutes | 1 container for culvert recommendation | From where was the sample collected | Source |
First name of sampler or witnessed by | Dan | Last name of sampler or witnessed by | Curran |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | D79409 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 824113 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-TRI-299-53.06, 0.5 below OG | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-02-06-28
DIME Test ID: 2024-02-06-28-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2024-05-20
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 02/16/2024
Minimum soil resistance of the lab measurement: 8600 Ohms
Soil sample temperature: 22.4 C
Soil box constant: 1
pH of soil: 7.49
Minimum soil resistance corrected to 15.5: 10083.5 Ohm-cm
Minimum soil resistivity at 15.5: 10084 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=7.49, p=10084.Ω∙cm
Test was verified on 5/20/2024 ✔