Summary for Test 2024-02-20-8-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993815
DEA: 081C0814
EFIS: 0816000086
DIST-CO-RTE-PM08-RIV-10-R60.7/R74.3
Award Date03/28/2022
Closeout Date01/21/2026
Work DescriptionI-10 PAVEMENT REHABILITATION (SEGMENT 1) PROJECT
Location DescriptionCoachella
QA Service Level1 (Verified on 05/03/2022)

Sample Information

Sample Taken Date02/20/2024 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing02/28/2024 Sample typeQuality Assurance
A brief description of the sampleD250 L Bar Lock Standard Coupler The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byEric
Last name of sampler or witnessed byFigueroa Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameDayton Superior
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#6 Coupler ModelD250L Bar Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)MM20102407 Y4234 Rebar Heat Number(s)4134894
Rebar Size 2 Coupler Unique IDSL-17-06

Test Details

DIME Sample ID: 2024-02-20-8
DIME Test ID: 2024-02-20-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-03-04

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 03/04/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 6/19mm100.443965090115Service Spliceaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 3/4/2024 ✔