Summary for Test 2024-02-28-13-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date02/28/2024 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/28/2024
Sample typeQuality Assurance A brief description of the sampleNative Structural Backfill
The quantity of what the sample constitutesPretesting new material for use on project From where was the sample collectedJob Site
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byRingler
Title of samplerLab Technician Telephone number of sampler7078161520
Laboratory sample identificationCon_24_077 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNative Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedFrom mini stockpiles at jobsite from multiple locations stations 549+00, 552+00 and 555+00
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2024-02-28-13
DIME Test ID: 2024-02-28-13-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-03-01

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 02/29/2024
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 99 %
Cumulative percent passing the 3/4 in. sieve: 98 %
Cumulative percent passing the 1/2 in. sieve: 92 %
Cumulative percent passing the 3/8 in. sieve: 88 %
Cumulative percent passing the #4 sieve: 78 %
Cumulative percent passing the #8 sieve: 74 %
Cumulative percent passing the #16 sieve: 70 %
Cumulative percent passing the #30 sieve: 67 %
Cumulative percent passing the #50 sieve: 62 %
Cumulative percent passing the #100 sieve: 37 %
Cumulative percent passing the #200 sieve: 21 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/1/2024