Summary for Test 2017-05-01-6-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/01/2017 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing05/09/2017 Sample typeQuality Assurance
A brief description of the sampleF1554 anchor rods The quantity of what the sample constitutes14
From where was the sample collectedManufacturer First name of sampler or witnessed byDaniel
Last name of sampler or witnessed byReyes Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameA M Bolt
Transportation Laboratory (TL) NumberNA Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3068594, 580287 03, 3066884 Retest Nut Mfg. Lot Number(s)35899A, 71849440
Washer Mfg. Lot Number(s)297736, 297792 Bolt SpecificationF1554 Grade 55
Bolt Length(s)18", 42", 12" Nut SpecificationA194 2H HDG
Washer SpecificationF436 HDG FinishHDG
Diameter/Size.75, 2.25, .625 Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2017-05-01-6
DIME Test ID: 2017-05-01-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-05-26

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/18/2017
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11AB301-114-173/4\"59057262.7Nut Proof LoadBrian

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 5/19/2017 ✔