Summary for Test 2024-01-30-26-2
Test performed: AASHTO T269-14Project Information
Project Identifiers | Project ID: 214649 DEA: 07316004 EFIS: 0715000194 |
---|---|
DIST-CO-RTE-PM | 07-LA-14-60.70 |
Award Date | 02/07/2023 |
Closeout Date | Not set |
Work Description | REHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES. |
Location Description | ROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE. |
QA Service Level | 1 (Verified on 01/29/2020) |
Sample Information
Sample Taken Date | 01/30/2024 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/31/2024 |
Sample type | Production Start-Up | A brief description of the sample | 3/4" HMA-A-SP R15 0.50%LAS |
The quantity of what the sample constitutes | 13 Boxes Production Start Up | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Avo | Last name of sampler or witnessed by | K. |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 0105A-24 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan HMA- Palmdale | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 221534 PAL VLO |
Test Details
DIME Sample ID: 2024-01-30-26
DIME Test ID: 2024-01-30-26-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-02-29
Test Results
Number of tests: 3
Input Type: Calculated
Tester's full name: Joseph Do
Date of test: 02/03/2024
Percent Air Voids: 3.1 %
Percent Air Voids 2: 3.3 %
Percent Air Voids 3: 3.5 %
Percent Air Voids Average: 3.3 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/29/2024 ✔