Summary for Test 2024-02-23-21-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 994397
DEA: 073393U4
EFIS: 0722000031
DIST-CO-RTE-PM07-LA-605-R11.4/R19.5
Award Date02/14/2023
Closeout Date03/13/2025
Work DescriptionCONSTRUCT DPPIA DEVICES AND MODIFY LIGHTING SYSTEMS.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF SLAUSON AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF VALLEY BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 07/13/2023)

Sample Information

Sample Taken Date02/23/2024 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/29/2024
Sample typeVerification A brief description of the sampleAsphalt Rubber Binder
The quantity of what the sample constitutes1qt. From where was the sample collectedSource
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byZubieta
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2024-02-23-21
DIME Test ID: 2024-02-23-21-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2024-03-12

Test Results


Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 02/29/2024
Temperature: 25 C
Ball Penetration (P1): 2 mm
Final Dial reading (F1): 76 mm
Ball Penetration (P2): 1 mm
Final Dial reading (F2): 74 mm
Ball Penetration (P3): 1 mm
Final Dial reading (F3): 74 mm
Resilience 1: 26 %
Resilience 2: 27 %
Resilience 3: 27 %
Average Resilience: 27 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/12/2024