Summary for Test 2024-02-06-16-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 1000130 DEA: 021J3504 EFIS: 0220000061 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-29-41.1/55.3 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Diddy Roost Culverts - Drainage System Restoration |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 10/24/2024) |
Sample Information
| Sample Taken Date | 02/06/2024 | Sample Unique Key | 16 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/06/2024 |
| Sample type | Preliminary | A brief description of the sample | Soil for culvert recommendation, C-4 |
| The quantity of what the sample constitutes | 1 container for culvert recommendation | From where was the sample collected | Source |
| First name of sampler or witnessed by | Terry | Last name of sampler or witnessed by | Schmitt |
| Title of sampler | MREAS | Telephone number of sampler | |
| Laboratory sample identification | D79401 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 897804 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 02-SHA-299-52.02, 0.5' ft. streambed inlet | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-02-06-16
DIME Test ID: 2024-02-06-16-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2024-05-20
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 02/12/2024
Minimum soil resistance of the lab measurement: 3150 Ohms
Soil sample temperature: 21.8 C
Soil box constant: 1
pH of soil: 6.22
Minimum soil resistance corrected to 15.5: 3646.13 Ohm-cm
Minimum soil resistivity at 15.5: 3646 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.22, p=3646.Ω∙cm
Test was verified on 5/20/2024 ✔