Summary for Test 2024-02-23-9-4
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676 |
---|---|
DIST-CO-RTE-PM | 04-SOL-80-R10.4/30.2 |
Award Date | 01/18/2022 |
Closeout Date | Not set |
Work Description | Highway widening, overhead signs, and electronic toll system. |
Location Description | In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
Sample Taken Date | 02/23/2024 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/23/2024 |
Sample type | Quality Assurance | A brief description of the sample | PCC Aggregates |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Ringler |
Title of sampler | Lab Technician | Telephone number of sampler | 7078161520 |
Laboratory sample identification | Con_24_071 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Cemex Fairfield | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Cemex |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Sample collected from belt at the Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | 1615759 | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-02-23-9
DIME Test ID: 2024-02-23-9-4
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-02-26
Test Results
Number of tests: 1
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 02/26/2024
Temperature correction: 0
Temperature of solution: 73
Clay reading (test 1): 45
Sand reading (test 1): 37
Sand equivalent (test 1): 83
Sand equivalent before temperature correction: 83
Sand equivalent after temperature correction: 83
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/26/2024 ✔