Summary for Test 2017-05-05-10-2

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 211718
DEA: 120H5304
EFIS: 1213000147
DIST-CO-RTE-PM12-ORA-5-6.8,22.8
Award Date11/10/2016
Closeout Date08/27/2018
Work DescriptionBRIDGE RAIL UPGRADE AND DECK REPLACEMENT
Location DescriptionORANGE COUNTY IN SAN JUAN CAPISTRANO AND IRVINE AT NORTHBOUND CAMINO LAS RAMBLAS LOOP ON RAMP AND NEAR BEE CANYON CREEK
QA Service Level1 (Verified on 01/18/2017)

Sample Information

Sample Taken Date05/05/2017 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing05/15/2017 Sample typeQuality Assurance
A brief description of the sampleBarsplice Button Head End Anchor The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byRussel
Last name of sampler or witnessed byLynch Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCascade Barsplice
Transportation Laboratory (TL) NumberC970155 Inspector Lot Number from the Transportation Laboratory (TL) FormL9606217
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)412716 Head Manufacturer Lot Number(s)1
Rebar Size#11 Headed Bar Model NameBarsplice Buttonhead 10AB
Size of HeadReduced Size - 4x Head Connection TypeCrimped Head
Head ShapeCircular Rebar ManufacturerCascade
Head ManufacturerBarsplice Head FabricatorBarsplice
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2017-05-05-10
DIME Test ID: 2017-05-05-10-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-05-23

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/16/2017
UTM: 400KIP
Temperature: 72 F
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
111.5615396098690Bar BrokeFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/16/2017 ✔