Summary for Test 2017-05-05-6-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 211935
DEA: 101F2604
EFIS: 1016000081
DIST-CO-RTE-PM10-CAL,MER-4,33,59,99,152-Var
Award Date02/17/2017
Closeout Date01/24/2018
Work DescriptionREPLACE JOINT SEALS, TREAT BRIDGE DECKS, AND REPLACE APPROACH SLABS.
Location DescriptionCALAVERAS AND MERCED COUNTIES AT VARIOUS LOCATIONS
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/05/2017 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing05/05/2017 Sample typeQuality Control
A brief description of the sample1 gallon can The quantity of what the sample constitutes2 tankers
From where was the sample collectedSource First name of sampler or witnessed byChris
Last name of sampler or witnessed byNunes Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameKwik bond and Reichhold
Transportation Laboratory (TL) NumberSacramento Caltrans lab Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1049325
Batch Number1049325 Mix number1049325

Test Details

DIME Sample ID: 2017-05-05-6
DIME Test ID: 2017-05-05-6-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-05-25

Test Results


Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 05/16/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 99 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 62.4 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2995 psi
Styrene ASTM D 2369 40% to 50 %: 46 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 579 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.2 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/25/2017 ✔