Summary for Test 2024-02-22-8-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994144 DEA: 060W15V4 EFIS: 0619000107 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-58,204-R53.4/R54.5,R0.0/4.6 |
| Award Date | 10/06/2022 |
| Closeout Date | 05/09/2025 |
| Work Description | MODIFY SIGNAL AND LIGHTING SYSTEMS AND REPLACE CURB RAMPS. |
| Location Description | KERN COUNTY IN BAKERSFIELD ON ROUTE 58 FROM SOUTH H STREET OVERCROSSING TO ROUTE 204 AND ON ROUTE 204 FROM ROUTE 58/204 SEPARATION TO L STREET |
| QA Service Level | 1 (Verified on 07/28/2022) |
Sample Information
| Sample Taken Date | 02/22/2024 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/22/2024 |
| Sample type | Department Acceptance | A brief description of the sample | 3/4 HMA Type A |
| The quantity of what the sample constitutes | L1SL19 | From where was the sample collected | Source |
| First name of sampler or witnessed by | James | Last name of sampler or witnessed by | Watson |
| Title of sampler | Material Tester | Telephone number of sampler | 15599773442 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Granite Solari | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 19 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-02-22-8
DIME Test ID: 2024-02-22-8-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-02-23
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 02/22/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4239.5 g
Mass of the specimen and specimen basket assembly prior to ignition: 6363.7 g
Mass of HMA Sample prior to ignition: 2124.2 g
Mass Loss: 112.2 g
Mass of aggregate remaining after ignition: 2012.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.41 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.87 %
General comments (publicly viewable) (Max 1000 characters): L1SL19
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 06-0W15V4_37020_240222_L1SL19_T308_HMA | 103.24 KB | 02/23/2024 | 2024-02-22-8-2 | Info |
Test was verified on 2/23/2024 ✔