Summary for Test 2024-01-18-40-2
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 994325 DEA: 044J4904 EFIS: 0415000356 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-13-6.7/7.2 |
| Award Date | 01/09/2023 |
| Closeout Date | 11/27/2024 |
| Work Description | CONSTRUCT CONCRETE BARRIERS AND BARRIER SLAB, COLD PLANE AND OVERLAY. |
| Location Description | ALAMEDA COUNTY IN OAKLAND FROM 0.2 MILE NORTH OF LINCOLN AVENUE OVERCROSSING TO 0.2 MILE SOUTH OF PARK BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 10/14/2022) |
Sample Information
| Sample Taken Date | 01/18/2024 | Sample Unique Key | 40 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/19/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
| The quantity of what the sample constitutes | 6 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Amy | Last name of sampler or witnessed by | Muela |
| Title of sampler | Quality Control Technician | Telephone number of sampler | |
| Laboratory sample identification | Set 2 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Ecoterra Ready Mix | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 7SK5K1X425F |
|---|---|---|---|
| The truck number from where the sample was collected | Load 12 Truck 1 | The batch plant ticket number from where the sample was collected | na |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | Set 2 | |
| A detailed description of where the material sample was collected | Truck 1, STA 146+50 | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-01-18-40
DIME Test ID: 2024-01-18-40-2
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-02-21
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Travis Van-Y
Date of test: 02/15/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Average diameter of cylinder 3: 6.00 in
Maximum load on cylinder 1: 213430 lb
Maximum load on cylinder 2: 215950 lb
Maximum load on cylinder 3: 220750 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Cross sectional area of cylinder 3: 28.27 in^2
Compressive strength (to nearest 10 psi): 7670 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/21/2024 ✔
