Summary for Test 2023-07-31-89-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994595
DEA: 081M2204
EFIS: 0821000094
DIST-CO-RTE-PM08-SBD-15,138,173-Var
Award Date05/24/2023
Closeout Date08/30/2024
Work DescriptionPOLYESTER CONCRETE OVERLAY AND REPLACE JOINT SEALS.
Location DescriptionSAN BERNARDINO COUNTY AT VARIOUS LOCATIONS.
QA Service Level1 (Verified on 07/18/2023)

Sample Information

Sample Taken Date07/31/2023 Sample Unique Key89
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/20/2024
Sample typeQuality Assurance A brief description of the sample#5 Bar Lock D250SCA Couplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byRAVINDER Last name of sampler or witnessed bySingh
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCascade Dayton Superior Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelBar Lock D250sca
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)4000005511 Rebar Heat Number(s)155623
Rebar Size 2 Coupler Unique IDSL-17-01

Test Details

DIME Sample ID: 2023-07-31-89
DIME Test ID: 2023-07-31-89-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-02-21

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 02/21/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 5/16mm200.312930194519Service Spliceaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 2/21/2024