Summary for Test 2022-08-19-81-5
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 3956 DEA: 07210804 |
---|---|
DIST-CO-RTE-PM | 07-LA-57,64-0 |
Award Date | 01/05/2007 |
Closeout Date | 08/25/2010 |
Work Description | CONSTRUCT TRAINING FACILITY |
Location Description | IN LOS ANGELES COUNTY IN LOSANGELES AT MAINTENANCE EQUIPMENTTRAINING CENTER |
QA Service Level | 1 (Verified on 08/26/2010) |
Sample Information
Sample Taken Date | 08/19/2022 | Sample Unique Key | 81 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 08/19/2022 |
Sample type | Verification | A brief description of the sample | pcc agg |
The quantity of what the sample constitutes | 80 cy | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Luis | Last name of sampler or witnessed by | Acosta |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | cemex fontana | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0040 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | stock pile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | 1610974 | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2022-08-19-81
DIME Test ID: 2022-08-19-81-5
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-02-22
Test Results
What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: David P
Date of test: 08/24/2022
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 97 %
Cumulative percent passing the 3/4 in. sieve: 84 %
Cumulative percent passing the 1/2 in. sieve: 57 %
Cumulative percent passing the 3/8 in. sieve: 41 %
Cumulative percent passing the #4 sieve: 10 %
Cumulative percent passing the #8 sieve: 6 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/22/2024 ✔