Summary for Test 2024-01-12-19-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 995263
DEA: 061G3304
EFIS: 0624000029
DIST-CO-RTE-PM06-FRE-180-118/138
Award Date08/21/2023
Closeout Date05/09/2025
Work DescriptionFRE 180 Emergency Slope Repairs.
Location DescriptionNot set
QA Service Level1 (Verified on 10/20/2023)

Sample Information

Sample Taken Date01/12/2024 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/16/2024
Sample typeDepartment Acceptance A brief description of the sampleHSR Wet Hole Concrete
The quantity of what the sample constitutes32 From where was the sample collectedJob Site
First name of sampler or witnessed bySok Last name of sampler or witnessed byThun
Title of samplerAssistant Structure Representative Telephone number of sampler5595199703
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameOutback Materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier06-1G3304
Structure nameSoldier Pile Wall Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number40F5G07
The truck number from where the sample was collected111 The batch plant ticket number from where the sample was collected152700
Concrete batch plantOutback Materials The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from the truck Where the material sample would have been placed if not sampledSoldier pile #6
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-01-12-19
DIME Test ID: 2024-01-12-19-2
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-02-16

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 02/09/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 3.99 in
Maximum load on cylinder 1: 88080 lb
Maximum load on cylinder 2: 85780 lb
Maximum load on cylinder 3: 87680 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.5 in^2
Compressive strength of cylinder 1: 7007.2 psi
Compressive strength of cylinder 2: 6824.2 psi
Compressive strength of cylinder 3: 7014.4 psi
Compressive strength (to nearest 10 psi): 6950 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/16/2024