Summary for Test 2024-02-12-28-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 994812
DEA: 042K7204
EFIS: 0417000014
DIST-CO-RTE-PM04-CC-4-R14.3/24.3
Award Date03/23/2023
Closeout Date10/06/2025
Work DescriptionPvmt rehabilitation, slab repl, ADA curb ramp and install guardrail.
Location DescriptionOn state highway in Contra Costa County in and near Concord and Pittsburg from 0.3 miles east of Peralta Road Undercrossing to Loveridge Road Overcrossing.
QA Service Level1 (Verified on 05/10/2023)

Sample Information

Sample Taken Date02/12/2024 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/12/2024
Sample typeQuality Assurance A brief description of the samplePCC Aggregates
The quantity of what the sample constitutes8 CY From where was the sample collectedSupplier
First name of sampler or witnessed byNick Last name of sampler or witnessed byHall
Title of samplerLab Technician Telephone number of sampler7072999133
Laboratory sample identificationCon_24_056 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCentral Pinole Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Vulcan Materials
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSampled from the Belt @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberD20119EA Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-02-12-28
DIME Test ID: 2024-02-12-28-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-02-14

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 02/13/2024
Sieve SizeCumulative Percent Passing
100 %
100 %
92 %
55 %
31 %
5 %
1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/14/2024