Summary for Test 2024-01-08-64-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 993141 DEA: 060V1204 EFIS: 0616000207 |
---|---|
DIST-CO-RTE-PM | 06-MAD-99-R6.9/R7.6 |
Award Date | 06/22/2022 |
Closeout Date | Not set |
Work Description | Cottonwood Creek Bridge Replacement - REPLACE BRIDGES AND CONSTRUCT RETAINING WALLS. |
Location Description | MADERA COUNTY NEAR MADERA FROM 0.4 MILE SOUTH OF COTTONWOOD CREEK BRIDGE TO 0.1 MILE NORTH OF AVENUE 12 OVERCROSSING |
QA Service Level | 1 (Verified on 07/28/2021) |
Sample Information
Sample Taken Date | 01/08/2024 | Sample Unique Key | 64 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/09/2024 |
Sample type | Quality Assurance | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | 7 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Lovett |
Title of sampler | QC Field Technician | Telephone number of sampler | |
Laboratory sample identification | Mix ND22023 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Builders Concrete Sanger | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | RD22023 |
---|---|---|---|
The truck number from where the sample was collected | Load 2 | The batch plant ticket number from where the sample was collected | 0 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | Set 1 | |
A detailed description of where the material sample was collected | S/B RTE 99 Barrier Wall Left, STA 113+95 | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-01-08-64
DIME Test ID: 2024-01-08-64-1
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-02-14
Test Results
Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Michael Kaus
Date of test: 01/15/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 59560 lb
Type of fracture pattern of cylinder 1: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 4740 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/14/2024 ✔