Summary for Test 2023-08-14-98-4

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 994387
DEA: 023J7704
EFIS: 0222000082
DIST-CO-RTE-PM02-SIS-96-97.2/103.0
Award Date12/23/2022
Closeout Date04/11/2024
Work DescriptionRHMA OVERLAY, REPLACE AC SURFACING, GUARDRAIL AND TRAFFIC STRIPE.
Location DescriptionSISKIYOU COUNTY ABOUT 21 MILES EAST OF HORSE CREEK FROM 4.2 MILES EAST OF EMPIRE CREEK BRIDGE TO 0.4 MILE WEST OF ROUTE 263
QA Service Level1 (Verified on 03/28/2023)

Sample Information

Sample Taken Date08/14/2023 Sample Unique Key98
Date that the sample was received by the laboratory/organization performing the testing08/14/2023 Sample typeProduction Start-Up
A brief description of the sampleCombined Untreated 1/2-inch Type G Aggregate The quantity of what the sample constitutesProduction Start-Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byJoe
Last name of sampler or witnessed byDelgado Title of sampler
Telephone number of sampler Laboratory sample identificationD79324F
Linked DIME Sample ID The fabricator/manufacturer/facility nameTullis — Northstate Asphalt (Redding, CA)
Transportation Laboratory (TL) Number841613 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057:: Shasta Ranch Aggregates (Anderson, CA)
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedLaboratory Batched from Sized Untreated Stockpile Samples
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-08-14-98
DIME Test ID: 2023-08-14-98-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-02-12

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 02/08/2024
Clay Level (Test 1): 6
Sand Level (Test 1): 4.4
Clay Level (Test 2): 6
Sand Level (Test 2): 4.3
Clay Level (Test 3): 6.2
Sand Level (Test 3): 4.4
Sand Equivalent (Test 1): 74
Sand Equivalent (Test 2): 72
Sand Equivalent (Test 3): 71
Sand Equivalent: 73
General comments (publicly viewable) (Max 1000 characters): SE=73

Test was verified on 2/12/2024 ✔