Summary for Test 2024-02-02-11-5
Test performed: AASHTO T316-17Project Information
| Project Identifiers | Project ID: 993815 DEA: 081C0814 EFIS: 0816000086 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-10-R60.7/R74.3 |
| Award Date | 03/28/2022 |
| Closeout Date | Not set |
| Work Description | I-10 PAVEMENT REHABILITATION (SEGMENT 1) PROJECT |
| Location Description | Coachella |
| QA Service Level | 1 (Verified on 05/03/2022) |
Sample Information
| Sample Taken Date | 02/02/2024 | Sample Unique Key | 11 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/05/2024 |
| Sample type | Verification | A brief description of the sample | Asphalt Binder Sample |
| The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Source |
| First name of sampler or witnessed by | Rigoberto | Last name of sampler or witnessed by | Arroyo |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Martin Marietta-Coachella | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Wilmington CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2024-02-02-11
DIME Test ID: 2024-02-02-11-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-02-27
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 02/12/2024
Time of test: 08:40 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 53.7 %
Viscosity reading #1 (A) : 0.266 Pa-s
Viscosity reading #2 (B) : 0.269 Pa-s
Viscosity reading #3 (C): 0.269 Pa-s
Average viscosity: 0.268 Pa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/27/2024 ✔