Summary for Test 2024-02-02-11-5

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 993815
DEA: 081C0814
EFIS: 0816000086
DIST-CO-RTE-PM08-RIV-10-R60.7/R74.3
Award Date03/28/2022
Closeout DateNot set
Work DescriptionI-10 PAVEMENT REHABILITATION (SEGMENT 1) PROJECT
Location DescriptionCoachella
QA Service Level1 (Verified on 05/03/2022)

Sample Information

Sample Taken Date02/02/2024 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/05/2024
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byArroyo
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta-Coachella Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-02-02-11
DIME Test ID: 2024-02-02-11-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-02-27

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 02/12/2024
Time of test: 08:40 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 53.7 %
Viscosity reading #1 (A) : 0.266 Pa-s
Viscosity reading #2 (B) : 0.269 Pa-s
Viscosity reading #3 (C): 0.269 Pa-s
Average viscosity: 0.268 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/27/2024