Summary for Test 2024-02-08-10-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994332
DEA: 11430444
EFIS: 1118000204
DIST-CO-RTE-PM11-IMP-8,78-Var
Award Date12/22/2022
Closeout DateNot set
Work DescriptionREHABILITATE BRIDGES, CONCRETE BARRIERS, TERMINAL SYSTEMS, ELECTRICAL.
Location DescriptionIMPERIAL COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 02/21/2023)

Sample Information

Sample Taken Date02/08/2024 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/09/2024
Sample typeQuality Assurance A brief description of the sampleBarsplice Taper Griptwist coupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byPheonix Last name of sampler or witnessed byBrealey
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameField Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelBarsplice Taper Grip-Twist
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A222815, A223677 Rebar Heat Number(s)3123643
Rebar Size 2 Coupler Unique IDSS-17-03

Test Details

DIME Sample ID: 2024-02-08-10
DIME Test ID: 2024-02-08-10-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-02-14

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 02/12/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13No. 11/36mm101.5613801188469Service Spliceaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 2/14/2024