Summary for Test 2024-01-30-24-1
Test performed: AASHTO T308-10
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
Project Identifiers | Project ID: 214486 DEA: 080K1224 EFIS: 0815000244 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-R28.6/37.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT |
Location Description | SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 01/30/2024 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/31/2024 |
Sample type | Department Acceptance | A brief description of the sample | 1/2" HMA-A-SP R25 1%LSM |
The quantity of what the sample constitutes | 2 BOXES OF HMA, 1 QT OIL | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | ALBERTO | Last name of sampler or witnessed by | PREDA-GONZALES |
Title of sampler | QC | Telephone number of sampler | |
Laboratory sample identification | 0103A-24 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Blue Diamond Materials-Victorville | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 19 | HMA Mix Number | 300215 |
Test Details
DIME Sample ID: 2024-01-30-24
DIME Test ID: 2024-01-30-24-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-02-06
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 02/01/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1602.0 g
Mass Loss: 99.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.62 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.49 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/6/2024 ✔
Warning: The test results shown on this page have been superseded and are invalid.