Summary for Test 2024-01-30-25-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 214486 DEA: 080K1224 EFIS: 0815000244 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-R28.6/37.5 |
| Award Date | 09/24/2021 |
| Closeout Date | 11/03/2025 |
| Work Description | REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT |
| Location Description | SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
| Sample Taken Date | 01/30/2024 | Sample Unique Key | 25 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/31/2024 |
| Sample type | Department Acceptance | A brief description of the sample | 1" HMA-A-SP R25 1%LSM |
| The quantity of what the sample constitutes | 2 BOXES HMA 98.30 TONS OUT | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | ALBERTO | Last name of sampler or witnessed by | PREDO-GONZALES |
| Title of sampler | QC | Telephone number of sampler | |
| Laboratory sample identification | 0104A-24 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Blue Diamond-Victorville | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1 inch | Lot number | 3 |
| Sublot number | 44 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-01-30-25
DIME Test ID: 2024-01-30-25-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-02-06
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 02/01/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2547.0 g
Mass Loss: 112.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.56 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.12 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 3.73 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/6/2024 ✔