Summary for Test 2024-01-04-36-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 994443 DEA: 053307C4 EFIS: 0514000028 |
---|---|
DIST-CO-RTE-PM | 05-SLO-41,46-44.5/45.3,54.0/57.8 |
Award Date | 02/27/2023 |
Closeout Date | Not set |
Work Description | Wye Segment - Route 41/46 Separation |
Location Description | Not set |
QA Service Level | 1 (Verified on 12/16/2022) |
Sample Information
Sample Taken Date | 01/04/2024 | Sample Unique Key | 36 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/05/2024 |
Sample type | Quality Assurance | A brief description of the sample | 4x8 Concrete Cylinders |
The quantity of what the sample constitutes | Trial Batch - 3F36H000 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kyle | Last name of sampler or witnessed by | Engen |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Holliday Rock - Paso Robles | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 3F36H000 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | NA | |
Concrete batch plant | Holliday Rock Company | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | Mix Truck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-01-04-36
DIME Test ID: 2024-01-04-36-1
Testing Lab: CT D05 - Whitley Gardens Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-02-02
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: S. Zepeda
Date of test: 02/01/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.09 in
Maximum load on cylinder 1: 85265 lb
Maximum load on cylinder 2: 88751 lb
Maximum load on cylinder 3: 79992 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 13.14 in^2
Compressive strength of cylinder 1: 6783.2 psi
Compressive strength of cylinder 2: 7027.0 psi
Compressive strength of cylinder 3: 6087.7 psi
Compressive strength (to nearest 10 psi): 6630 psi
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
05-3307C4_CTM 521_KEE_240104_3T36H000_28 Day_3x_1 | 84.94 KB | 02/02/2024 | 2024-01-04-36-1 | Info |
Test was verified on 2/2/2024 ✔