Summary for Test 2024-01-16-43-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 994191 DEA: 081G8304 EFIS: 0816000079 |
---|---|
DIST-CO-RTE-PM | 08-SBD-40-R100.8/R101.8 |
Award Date | 12/01/2022 |
Closeout Date | Not set |
Work Description | HMA, STRUCTURAL CONC, BAR REINFORCING STEEL, CRSP & IMPORTED BORROW. |
Location Description | SAN BERNARDINO COUNTY AT ESSEX FROM 1.1 MILES EAST OF ESSEX ROAD OVERCROSSING TO 0.5 MILE EAST OF HALFWAY HILLS WASH BRIDGE |
QA Service Level | 1 (Verified on 03/30/2023) |
Sample Information
Sample Taken Date | 01/16/2024 | Sample Unique Key | 43 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/06/2024 |
Sample type | Quality Assurance | A brief description of the sample | HRC Coupler 500/510 |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Amber | Last name of sampler or witnessed by | Christian |
Title of sampler | ASR | Telephone number of sampler | 928-216-0101 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Camblin Steel Service | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Vinton Steel |
Coupler Manufacturer | Vinton Steel | Intermediate Assembler or Fabricator | |
Rebar Size | #9 | Coupler Model | HRC 500-510 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | Heat 73131267/73131301 | Rebar Heat Number(s) | 9001221 |
Rebar Size 2 | Coupler Unique ID | TF-17-01 |
Test Details
DIME Sample ID: 2024-01-16-43
DIME Test ID: 2024-01-16-43-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-02-08
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 02/01/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID:
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | No. 9/29mm | 4 | 0 | 1 | 98425 | 98425 | Service Splice | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 2/8/2024 ✔