Summary for Test 2023-12-12-58-5
Test performed: CTM 504-June 2010Project Information
| Project Identifiers | Project ID: 993825 DEA: 040Q30U4 EFIS: 0420000235 COOP: 042830A3,042830A4 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA,CC-680-R11.0/R21.9,R0.0/R0.9 |
| Award Date | 11/23/2022 |
| Closeout Date | Not set |
| Work Description | PRECAST CONC PVMT, ELECTRONIC TOLL SYSTEM, JPCP, CB & STRUCTURAL CONC |
| Location Description | ALAMEDA AND CONTRA COSTA COUNTIES AT SUNOL AND IN SAN RAMON BETWEEN 0.4 MILE SOUTH OF CALAVERAS ROAD UNDERCROSSING TO 0.9 MILE NORTH OF ALCOSTA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 05/11/2022) |
Sample Information
| Sample Taken Date | 12/12/2023 | Sample Unique Key | 58 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/13/2023 |
| Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
| The quantity of what the sample constitutes | 4 Cylinder | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Rafael | Last name of sampler or witnessed by | Duenas |
| Title of sampler | QC Field Technician | Telephone number of sampler | |
| Laboratory sample identification | Mix D20119EA | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Central Concrete Pleasanton | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | D20119EA |
|---|---|---|---|
| The truck number from where the sample was collected | Load 6 | The batch plant ticket number from where the sample was collected | 0 |
| Concrete batch plant | Central Concrete Supply | The fabricator/manufacturer designation for the sample | Set 1 |
| A detailed description of where the material sample was collected | Truck Mixer | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-12-12-58
DIME Test ID: 2023-12-12-58-5
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Test Release Date: 2024-02-01
Test Results
Input Type: Calculated
Tester's full name: Rafael Duenas
Date of test: 12/12/2023
Air Content: 1.1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/1/2024 ✔
