Summary for Test 2024-01-18-26-4
Test performed: AASHTO T269-14Project Information
| Project Identifiers | Project ID: 994436 DEA: 11080284 EFIS: 1117000085 |
|---|---|
| DIST-CO-RTE-PM | 11-IMP-98-32.1/32.5 |
| Award Date | Not set |
| Closeout Date | 10/24/2024 |
| Work Description | Place HMA, minor concrete, modify drainage, landscape and electrical. |
| Location Description | IMPERIAL COUNTY IN CALEXICO FROM OLLIE AVENUE TO 0.1 MILE EAST OF ROCKWOOD AVENUE |
| QA Service Level | 1 (Verified on 12/09/2022) |
Sample Information
| Sample Taken Date | 01/18/2024 | Sample Unique Key | 26 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/25/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 1-1/2" HMA-A |
| The quantity of what the sample constitutes | 16 boxes 11 bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Loper |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 5307-PSU | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | API Gateway | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | Not Applicable | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | 16 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-01-18-26
DIME Test ID: 2024-01-18-26-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-03-08
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 01/30/2024
| 1 | 2 | 3 | ||||
|---|---|---|---|---|---|---|
| 2.417 | 2.404 | 2.398 | ||||
| 2.52 | ||||||
4.1 % | 4.6 % | 4.8 % | ||||
4.5 % | ||||||
General comments (publicly viewable) (Max 1000 characters): Complies Avg 4.5 Target 5.0% +/- 1.5%
Test was verified on 3/8/2024 ✔