Summary for Test 2017-04-13-9-5
Test performed: ASTM A416-15Project Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 04/13/2017 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/28/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Prestressing Strand |
| The quantity of what the sample constitutes | 50 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Dan | Last name of sampler or witnessed by | Hiranaga |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | Number of Coils | 50 | |
| Group Number | 10858 | Strand Diameter | .5 in |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | S0290090 S0290091 S0290092 S0290660 S0290662 S0290665 S0290667 S0290668 S0290682 S0505217 S0505517 S0505617 S0505917 S0522316 S0522416 S0522816-2 S0523216-2 S0523316-2 S0523616 S0533517 S0533617 | Mfg. Lot Number(s) | na |
| Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2017-04-13-9
DIME Test ID: 2017-04-13-9-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2017-05-15
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Arnold
Date of test: 05/04/2017
UTM: 120KIP
Temperature: 70 F
Extensometers: E88766
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | S0290092 | S529960-2 | 0.148 | 43374 | 40505 | 29.1 | 1.67 | Arnold |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 5/8/2017 ✔