Summary for Test 2017-04-28-5-2

Test performed: ASTM A722-15

Project Information

Project IdentifiersProject ID: 210794
DEA: 062HT104
EFIS: 0612000287
DIST-CO-RTE-PM06-FRE-99-23.5/26.7
Award Date06/30/2016
Closeout Date09/16/2020
Work Description(Alternative Delivery) Realign Freeway CONTACT SMR PRIOR TO PERFORMING ANY TESTING OR INSPECTION. CMGC PROJECT. Realign Route 99 between Ashlan Avenue and Olive Avenue to accommodate the High Speed Train (HST).
Location DescriptionState Highway 99 in Fresno (Fresno County) from 0.2 miles North of Olive Ave over-crossing to 0.2 miles North of Ashlan Ave over-crossing.
QA Service Level1 (Verified on 10/01/2015)

Sample Information

Sample Taken Date04/28/2017 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing05/02/2017 Sample typeQuality Assurance
A brief description of the sampleA722 Threaded Bar The quantity of what the sample constitutes2
From where was the sample collectedManufacturer First name of sampler or witnessed byS
Last name of sampler or witnessed byKRISHNA Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameDSI Gerdau
Transportation Laboratory (TL) NumberC939810 Inspector Lot Number from the Transportation Laboratory (TL) FormL8800117
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypeDeformed Rebar Size1
Nut Specification for Threaded BarA519 System ManufacturerDSI
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)6213907905
Nut Heat Number(s)00A165145 Bar Lot NumberNA
Nut Lot NumberNA Coupler Heat Number(s)NA
Coupler GradeNA

Test Details

DIME Sample ID: 2017-04-28-5
DIME Test ID: 2017-04-28-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2017-05-11

Test Results


Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/03/2017
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
11A722 DSI 1 Threaded Bar Heat #6213907905 & L88001170.781759371463838.80A722 Bar & NutFred

General comments (publicly viewable) (Max 1000 characters): A722 Bar & Nut
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/4/2017 ✔