Summary for Test 2017-04-28-6-2
Test performed: ASTM A722-15Project Information
Project Identifiers | Project ID: 210794 DEA: 062HT104 EFIS: 0612000287 |
---|---|
DIST-CO-RTE-PM | 06-FRE-99-23.5/26.7 |
Award Date | 06/30/2016 |
Closeout Date | 09/16/2020 |
Work Description | (Alternative Delivery) Realign Freeway CONTACT SMR PRIOR TO PERFORMING ANY TESTING OR INSPECTION. CMGC PROJECT. Realign Route 99 between Ashlan Avenue and Olive Avenue to accommodate the High Speed Train (HST). |
Location Description | State Highway 99 in Fresno (Fresno County) from 0.2 miles North of Olive Ave over-crossing to 0.2 miles North of Ashlan Ave over-crossing. |
QA Service Level | 1 (Verified on 10/01/2015) |
Sample Information
Sample Taken Date | 04/28/2017 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/02/2017 |
Sample type | Quality Assurance | A brief description of the sample | A722 Threaded Bar |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | S | Last name of sampler or witnessed by | KRISHNA |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | DSI Gerdau | Transportation Laboratory (TL) Number | C939811 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L8800217 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A722 | Threaded Bar Grade | 150 |
Threaded Bar Type | Deformed | Rebar Size | 1 |
Nut Specification for Threaded Bar | A519 | System Manufacturer | DSI |
Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
Coating Standards | Uncoated | Bar Heat Number(s) | M672147 |
Nut Heat Number(s) | 00A165145 | Bar Lot Number | NA |
Nut Lot Number | NA | Coupler Heat Number(s) | NA |
Coupler Grade | NA |
Test Details
DIME Sample ID: 2017-04-28-6
DIME Test ID: 2017-04-28-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2017-05-11
Test Results
Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/03/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 2 | A722 DSI 1 Threaded Bar Heat #M672147 & Nut | L8800217 | 0.78 | 177787 | 159027 | 10 | 0 | A722 Bar & Nut | Fred |
General comments (publicly viewable) (Max 1000 characters): A722 Bar & Nut
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 5/4/2017 ✔