Summary for Test 2023-11-08-121-1

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 994803
DEA: 043J0704
EFIS: 0415000077
DIST-CO-RTE-PM04-CC-80-10.1/13.5
Award Date03/10/2023
Closeout Date10/06/2025
Work DescriptionRemove PCC and AC, place PCP and AC Resurfacing.
Location DescriptionConstruction on State Highway in Contra Costa County in Hercules and Crockett from Route 80/4 separation to 0.1 mile west of Crockett Viaduct.
QA Service Level1 (Verified on 05/10/2023)

Sample Information

Sample Taken Date11/08/2023 Sample Unique Key121
Date that the sample was received by the laboratory/organization performing the testing12/21/2023 Sample typeQuality Assurance
A brief description of the sample1/2" HMA and Cores The quantity of what the sample constitutes750 Tons
From where was the sample collectedSupplier First name of sampler or witnessed byNick
Last name of sampler or witnessed byHall Title of samplerLab Technician
Telephone number of sampler7072999133 Laboratory sample identificationRich_24_004
Linked DIME Sample ID The fabricator/manufacturer/facility nameCounty Asphalt Martinez
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number3
Sublot number2 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-11-08-121
DIME Test ID: 2023-11-08-121-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-02-05

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 01/11/2024
Specific Gravity for Sample 1: 2.599
Theoretical maximum density at 25°C (77°F): 2591 kg/m^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/5/2024 ✔