Summary for Test 2024-01-24-6-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 995260
DEA: 061G0504
EFIS: 0623000195
DIST-CO-RTE-PM06-FRE-VAR,(180),245-99/104, (99.0)/0.0/(104.0)/9.0
Award Date03/29/2023
Closeout DateNot set
Work DescriptionRoutes 180, 245 Emergency Slip Out Repair
Location DescriptionNot set
QA Service Level1 (Verified on 10/20/2023)

Sample Information

Sample Taken Date01/24/2024 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/23/2024
Sample typeQuality Assurance A brief description of the sampleStructural Backfill
The quantity of what the sample constitutes1 bag From where was the sample collectedManufacturer
First name of sampler or witnessed byye Last name of sampler or witnessed byYang
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Sanger Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0010
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-01-24-6
DIME Test ID: 2024-01-24-6-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-01-24

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Tomas Silva
Date of test: 01/24/2024
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 96 %
Cumulative percent passing the 1/2 in. sieve: 81 %
Cumulative percent passing the 3/8 in. sieve: 72 %
Cumulative percent passing the #4 sieve: 54 %
Cumulative percent passing the #8 sieve: 39 %
Cumulative percent passing the #16 sieve: 30 %
Cumulative percent passing the #30 sieve: 23 %
Cumulative percent passing the #50 sieve: 17 %
Cumulative percent passing the #100 sieve: 12 %
Cumulative percent passing the #200 sieve: 9.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/24/2024