Summary for Test 2024-01-24-6-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 995260 DEA: 061G0504 EFIS: 0623000195 |
---|---|
DIST-CO-RTE-PM | 06-FRE-VAR,(180),245-99/104, (99.0)/0.0/(104.0)/9.0 |
Award Date | 03/29/2023 |
Closeout Date | Not set |
Work Description | Routes 180, 245 Emergency Slip Out Repair |
Location Description | Not set |
QA Service Level | 1 (Verified on 10/20/2023) |
Sample Information
Sample Taken Date | 01/24/2024 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/23/2024 |
Sample type | Quality Assurance | A brief description of the sample | Structural Backfill |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | ye | Last name of sampler or witnessed by | Yang |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Sanger | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0010 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-01-24-6
DIME Test ID: 2024-01-24-6-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-01-24
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Tomas Silva
Date of test: 01/24/2024
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 96 %
Cumulative percent passing the 1/2 in. sieve: 81 %
Cumulative percent passing the 3/8 in. sieve: 72 %
Cumulative percent passing the #4 sieve: 54 %
Cumulative percent passing the #8 sieve: 39 %
Cumulative percent passing the #16 sieve: 30 %
Cumulative percent passing the #30 sieve: 23 %
Cumulative percent passing the #50 sieve: 17 %
Cumulative percent passing the #100 sieve: 12 %
Cumulative percent passing the #200 sieve: 9.2 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/24/2024 ✔