Summary for Test 2023-07-06-116-4
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 993297 DEA: 010F8204 EFIS: 0116000067 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-101-R90.1/109.6 |
| Award Date | 01/27/2022 |
| Closeout Date | 03/04/2024 |
| Work Description | PLACE RHMA-G AND HMA (TYPE A). |
| Location Description | IN HUMBOLDT COUNTY IN AND NEAR TRINIDAD FROM 1.3 MILES SOUTH OF SCHOOL ROAD OVERCROSSING TO 0.4 MILE NORTH OF BIG LAGOON BRIDGE |
| QA Service Level | 1 (Verified on 10/12/2021) |
Sample Information
| Sample Taken Date | 07/06/2023 | Sample Unique Key | 116 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/08/2023 |
| Sample type | Dispute Resolution | A brief description of the sample | 12 boxes of 1/2-inch RHMA-G (PG 64-16 CR) with WMA |
| The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Jon | Last name of sampler or witnessed by | Atturio |
| Title of sampler | Witnessed by Jayce Brown | Telephone number of sampler | |
| Laboratory sample identification | D79313 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Mercer-Fraser — Plant B (Fortuna, CA) | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-07-06-116
DIME Test ID: 2023-07-06-116-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2024-01-23
Test Results
Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method:
Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 08/24/2023
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 1.13 mm
Maximum impression at 5000 passes (right wheel): 1.11 mm
Average impression at 5000 passes (left/right avg): 1.12 mm
Maximum impression at 10000 passes (left wheel): 1.49 mm
Maximum impression at 10000 passes (right wheel): 1.52 mm
Average impression at 10000 passes (left/right avg): 1.51 mm
Maximum impression at 15000 passes (left wheel): 1.87 mm
Maximum impression at 15000 passes (right wheel): 1.87 mm
Average impression at 15000 passes (left/right avg): 1.87 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): Nf>15000,
SIP>15000
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| D79313, ______, 01-0F8203, HWT | 818.38 KB | 01/23/2024 | 2023-07-06-116-4 | Info |
Test was verified on 1/23/2024 ✔