Summary for Test 2023-10-26-34-2
Test performed: ASTM C39-21Project Information
| Project Identifiers | Project ID: 994191 DEA: 081G8304 EFIS: 0816000079 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-40-R100.8/R101.8 |
| Award Date | 02/07/2023 |
| Closeout Date | 08/29/2025 |
| Work Description | HMA, STRUCTURAL CONC, BAR REINFORCING STEEL, CRSP & IMPORTED BORROW. |
| Location Description | SAN BERNARDINO COUNTY AT ESSEX FROM 1.1 MILES EAST OF ESSEX ROAD OVERCROSSING TO 0.5 MILE EAST OF HALFWAY HILLS WASH BRIDGE |
| QA Service Level | 1 (Verified on 03/30/2023) |
Sample Information
| Sample Taken Date | 10/26/2023 | Sample Unique Key | 34 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/28/2023 |
| Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinders |
| The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jegbefume | Last name of sampler or witnessed by | Adodo |
| Title of sampler | ASR | Telephone number of sampler | |
| Laboratory sample identification | 1053-6 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Cemex | Transportation Laboratory (TL) Number | 1053-6 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1629101 |
|---|---|---|---|
| The truck number from where the sample was collected | NA 1st truck | The batch plant ticket number from where the sample was collected | 44142025 |
| Concrete batch plant | Cemex | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | Halfway Hills Wash Bridge EB - Pier 3 and 4 | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-10-26-34
DIME Test ID: 2023-10-26-34-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-01-22
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 11/23/2023
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 3.99 in
Maximum load on cylinder 1: 63750 lb
Maximum load on cylinder 2: 63250 lb
Maximum load on cylinder 3: 62740 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 0 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.5 in^2
Compressive strength of cylinder 1: 5070.0 psi
Compressive strength of cylinder 2: 5030.0 psi
Compressive strength of cylinder 3: 5020 psi
Compressive strength (to nearest 10 psi): 5040 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/22/2024 ✔