Summary for Test 2023-11-08-101-8

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 214135
DEA: 09213404
EFIS: 0900000030
DIST-CO-RTE-PM09-INY-395-29.9/41.8
Award Date10/22/2021
Closeout DateNot set
Work DescriptionROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT.
Location DescriptionINYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE
QA Service Level1 (Verified on 05/03/2019)

Sample Information

Sample Taken Date11/08/2023 Sample Unique Key101
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/18/2023
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed byJared Last name of sampler or witnessed bykuplian
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTank at Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2023-11-08-101
DIME Test ID: 2023-11-08-101-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-01-18

Test Results


Phase: PAV residue
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 01/16/2024
Test Plate Diameter: 8 mm
Phase Angle (δ) (for the 10 cycles): 64.7 degree
(G*) x sin(δ)=: 4170 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/18/2024