Summary for Test 2024-01-16-6-2
Test performed: CTM 227-December 2014Project Information
| Project Identifiers | Project ID: 993782 DEA: 07339604 EFIS: 0717000157 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-14-R29.0/R29.5 |
| Award Date | 07/06/2022 |
| Closeout Date | 11/05/2025 |
| Work Description | CONSTRUCT SLOPE BETTERMENT. |
| Location Description | LOS ANGELES COUNTY IN SANTA CLARITA FROM 0.9 MILE NORTH OF PLACERITA CANYON ROAD UNDERCROSSING TO 0.2 MILE SOUTH OF GOLDEN VALLEY ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 05/11/2022) |
Sample Information
| Sample Taken Date | 01/16/2024 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/16/2024 | Sample type | Department Acceptance |
| A brief description of the sample | 3/8" X #8 PCC Aggregate | The quantity of what the sample constitutes | 120 CY |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Hopkins | Title of sampler | Plant Inspector |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | National RM Santa Clarita | |
| Transportation Laboratory (TL) Number | C011624A | Inspector Lot Number from the Transportation Laboratory (TL) Form | KH101A |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0046::BIG ROCK CREEK- GRANITE |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | National RM Santa Clarita | A detailed description of where the material sample was collected | Conveyor Belt |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
| The concrete mix design number | S72E250T7 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-01-16-6
DIME Test ID: 2024-01-16-6-2
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2024-01-29
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 01/16/2024
Top sediment column reading (single primary size): 0.4 in
Cleanness value (single primary size): 89
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/29/2024 ✔