Summary for Test 2024-01-08-41-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 995370
DEA: 072XG004
EFIS: 0723000145
DIST-CO-RTE-PM07-LA-2-40.3/46.1
Award Date03/22/2023
Closeout Date11/07/2024
Work DescriptionRemove the mudslide and rock slide behind the catchment wall, perform rock scaling, reconstruct the slope drapery protection system, rebuild the damaged slope with geogrid and subdrains, repair/replace the washed out roadway, construct earth berms and place erosion control on the washed out slopes
Location DescriptionNot set
QA Service Level1 (Verified on 01/22/2024)

Sample Information

Sample Taken Date01/08/2024 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/09/2024
Sample typeDepartment Acceptance A brief description of the sample4X8 PCC cylinders
The quantity of what the sample constitutes130 CY From where was the sample collectedJob Site
First name of sampler or witnessed byRoberto Last name of sampler or witnessed byAppaza
Title of samplerACI Telephone number of sampler
Laboratory sample identification24-001 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCal Portland Transportation Laboratory (TL) Number109313
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberNone
The truck number from where the sample was collectedNA The batch plant ticket number from where the sample was collectedNA
Concrete batch plantCal Portland The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-01-08-41
DIME Test ID: 2024-01-08-41-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-01-16

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Robert Achuela
Date of test: 01/15/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 78020 lb
Maximum load on cylinder 2: 80354 lb
Maximum load on cylinder 3: 81958 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 6177.4 psi
Compressive strength of cylinder 2: 6362.2 psi
Compressive strength of cylinder 3: 6489.2 psi
Compressive strength (to nearest 10 psi): 6340 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/16/2024