Summary for Test 2024-01-02-15-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 994191 DEA: 081G8304 EFIS: 0816000079 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-40-R100.8/R101.8 |
| Award Date | 02/07/2023 |
| Closeout Date | 08/29/2025 |
| Work Description | HMA, STRUCTURAL CONC, BAR REINFORCING STEEL, CRSP & IMPORTED BORROW. |
| Location Description | SAN BERNARDINO COUNTY AT ESSEX FROM 1.1 MILES EAST OF ESSEX ROAD OVERCROSSING TO 0.5 MILE EAST OF HALFWAY HILLS WASH BRIDGE |
| QA Service Level | 1 (Verified on 03/30/2023) |
Sample Information
| Sample Taken Date | 01/02/2024 | Sample Unique Key | 15 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/02/2024 |
| Sample type | Quality Assurance | A brief description of the sample | CTM231 TEST 01 |
| The quantity of what the sample constitutes | 507 Square Feet | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Erinberto | Last name of sampler or witnessed by | Aragon |
| Title of sampler | Caltrans Consultant | Telephone number of sampler | |
| Laboratory sample identification | 01022024 TEST 01 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | AT THE JOBSITE | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-01-02-15
DIME Test ID: 2024-01-02-15-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-01-08
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Erinberto Aragon
Date of test: 01/02/2024
Gage No.: 34188
Test No.: 1
Nuclear By: erinberto aragon
Non-Bias Plan No.: 1
Depth: 11
Material No.: NATIVE
Material Type: STRUCTURALL BACKFILL
Impact By: erinberto aragon
Standard Count Density: 1683 g/cc
Count or Density 1: 471 g/cc
Count or Density 2: 464 g/cc
Count or Density 3: 603 g/cc
Standard Count Moisture: 669 g/cc
Moisture Count 1: 118 g/cc
Moisture Count 2: 62 g/cc
Moisture Count 3: 96 g/cc
Sum of Count or Density: 1538 g/cc
Average of Count or Density: 513 g/cc
Sum of Moisture Count: 276 g/cc
Average of Moisture Count: 92 g/cc
Count Ratio Density: 0.3
Count Ratio Moisture: 0.14
Calculated Percent Relative Compaction: 91.8 %
Reported Percent Relative Compaction: 92 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/8/2024 ✔