Summary for Test 2023-12-15-30-3

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 994553
DEA: 032G7204
EFIS: 0322000151
DIST-CO-RTE-PM03-YOL-113-R10.1/R10.8
Award Date05/19/2023
Closeout Date05/23/2025
Work DescriptionJOINTED PLAIN CONC PVMT, INDIVIDUAL SLAB REPL, & REMOVE CONC PVMT.
Location DescriptionYOLO COUNTY IN WOODLAND FROM 0.1 MILE SOUTH OF EAST WOODLAND OVERHEAD TO 0.1 MILE SOUTH OF S5/S113 CONNECTOR UNDERCROSSING
QA Service Level1 (Verified on 05/15/2023)

Sample Information

Sample Taken Date12/15/2023 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing12/15/2023
Sample typeQuality Assurance A brief description of the sample3/4" HMA-SP Oil
The quantity of what the sample constitutes1 Oil Can From where was the sample collectedJob Site
First name of sampler or witnessed byMark Last name of sampler or witnessed byMahoney
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Woodland Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierPacific Northwest Oil - Stockton CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2023-12-15-30
DIME Test ID: 2023-12-15-30-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2024-01-05

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 01/05/2024
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 21.757 kPa
Phase Angle (δ) (for the 10 cycles): 50.3 degree
Complex Modulus (G*) (for the 10 measurements): 2164.829 kPa
Test Temperature (Specimen 1): 31.0 C
(G*) x sin(δ)=: 1666 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 1/5/2024